DIY HVAC Tools

Samsung mini split error codes

Samsung residential splits show three-digit E codes (E101, E554) on the indoor display. Samsung builds its own platform.

Covers: Wind-Free, Quantum, Max Heat, Free Joint Multi.

Type it exactly as the unit shows it. Not sure which brand? It is printed on the front of the indoor unit.

All Samsung codes

35 codes. Type to filter the list.

CodeMeaningTypeFix
E101Communication error between indoor and outdoor unitsFaultDIY checks
E102Communication error between indoor and outdoor unitsFaultDIY checks
E121Indoor room temperature sensor fault (open or short circuit)FaultDIY checks
E122Indoor evaporator inlet temperature sensor fault (open or short circuit)FaultDIY checks
E123Indoor evaporator outlet temperature sensor fault (open or short circuit)FaultDIY checks
E153Float switch operated (drain)FaultDIY
E154Indoor fan motor fault (no speed feedback)FaultDIY checks
E162Indoor unit EEPROM errorFaultTechnician
E163Indoor unit option setting errorFaultTechnician
E201Indoor unit count mismatch (multi-split)FaultDIY checks
E202Communication error between indoor and outdoor unitsFaultDIY checks
E203Communication error between outdoor main and inverter boardsFaultTechnician
E221Outdoor air temperature sensor fault (open or short circuit)FaultDIY checks
E231Outdoor condenser temperature sensor fault (open or short circuit)FaultDIY checks
E251Compressor discharge temperature sensor fault (open or short circuit)FaultDIY checks
E320Compressor OLP temperature sensor faultFaultDIY checks
E404Outdoor overload protection (heating)ProtectionDIY checks
E416Discharge temperature overheating protectionProtectionDIY checks
E440Heating blocked: outdoor temperature too highProtectionDIY
E441Cooling blocked: outdoor temperature too lowProtectionDIY
E458Outdoor fan motor faultFaultDIY checks
E461Compressor start failureProtectionTechnician
E462Total current limit or PFC over-currentProtectionDIY checks
E464IPM over-current (compressor)ProtectionTechnician
E465Compressor overload (voltage limit)ProtectionTechnician
E466DC link voltage abnormal (over or under)ProtectionDIY checks
E467Compressor rotation error (missing phase or stall)ProtectionTechnician
E468Current sensor faultFaultTechnician
E469DC link voltage sensor faultFaultTechnician
E471Outdoor unit EEPROM errorFaultTechnician
E474Inverter heat sink temperature sensor faultFaultDIY checks
E484PFC overloadProtectionTechnician
E485Input current sensor faultFaultTechnician
E500IPM (inverter) overheatingProtectionDIY checks
E554Refrigerant leak detected (low charge)FaultDIY checks

How Samsung shows error codes

The indoor display shows E followed by three digits (E101, E554). Units without a full display blink the indicator lamps in a pattern the manual decodes; the outdoor board's 7-segment display or LEDs show the same code. E1xx codes are indoor-unit faults, E2xx are communication faults, E4xx are outdoor sensors, protections and inverter faults, and E5xx are outdoor board and refrigerant faults.

Sources

  • Samsung residential split service manuals (error code tables)

Updated September 2026. Manufacturer site: www.samsunghvac.com