DIY HVAC Tools

Comfortmaker mini split error code U8

Indoor fan (PG motor) zero-crossing detection error.

  • TypeFault
  • SystemFan motor
  • Can I fix it?Homeowner checks, then maybe a tech
  • Applies toDLC4 / DLF4 series, 2013 to 2015 (Gree-built)

What U8 means on a Comfortmaker

On units with a PG-type indoor fan motor, the board lost the zero-crossing signal it uses to control the motor.

On this platform, U8 is a fault: something has failed or is disconnected and needs diagnosis.

Common causes

  • A loose fan motor plug.
  • A failed fan motor or its feedback circuit.
  • A failed indoor board.

How to fix it yourself

Work through the checks below first; they resolve most cases. If they do not, the repair itself may need a technician.

  1. Reset the system: switch the breaker (or the outdoor disconnect) off, wait a full five minutes so the boards fully discharge, then switch it back on and restart from the remote.
  2. Reseat the fan motor plug on the indoor board.
  3. Check that the blower wheel spins freely.

Switch off power at the breaker before opening either unit. Capacitors in the outdoor unit hold a charge for several minutes after power is cut.

When to call a technician

If the motor tests fine, the indoor board is the suspect.

Which Comfortmaker units show U8

This page applies to Comfortmaker DLCSRA / DLCSRB / DLCLRA outdoor with DLFSHA / DLFSFA indoor (2015 and later) and DLC4 / DLF4 (2013 to 2015) units on the DLC4 / DLF4 series, 2013 to 2015 (Gree-built). Comfortmaker's own documentation lists U8 as "Indoor fan (PG motor) zero-crossing detection error", the same definition used across the Gree platform it is built on. If your unit shows a code with a different shape (for example a four-character code, or a plain number), it is from a different table; use the lookup with your exact code.

Where Comfortmaker shows this code

DLC4 / DLF4 series, 2013 to 2015 (Gree-built): The code shows on the indoor unit's display in place of the temperature. If the display is off, press the Light button on the remote. Some models also count out the code as indicator blinks. E codes are system protections and faults, F codes are mostly sensor faults, H codes are outdoor and compressor protections, U codes are motor and valve faults, and P codes are power-supply faults.

Other Comfortmaker codes

Same part of the system as U8:

All Comfortmaker error codes

U8 on other brands

The same characters do not always mean the same thing. Check the brand on your unit.

Questions people ask

Can I reset a Comfortmaker U8 code myself?

Yes. Turn the system off at the breaker for five minutes, then restart it. If U8 comes back, the fault is real and needs the checks above.

Is it safe to keep running a Comfortmaker showing U8?

The unit will usually refuse to run, or run with reduced output, until the fault is cleared. Repeated resets do not fix anything and can mask a problem that is getting worse.

Do I need a technician for Comfortmaker U8?

Work through the checks below first; they resolve most cases. If they do not, the repair itself may need a technician. If the motor tests fine, the indoor board is the suspect.

Sources

  • ICP DLCSRA Outdoor Unit Single Zone Ductless Service Manual 32808000801 (error code table)
  • ICP ductless installation instructions IM-KSAIC04-04 (DLCPRA / DLCSRB / DLCERB / DLCLRA error codes)
  • ICP R-410A Ductless Split System Service Manual 421 01 9204 00 (DLC4 / DLF4, 2013)

Updated September 2026. Codes and definitions vary by model year. If your manual disagrees with this page, your manual wins. Send a correction.