DIY HVAC Tools

Blueridge mini split error code PC 44

Compressor zero-speed protection. Also shown as PC44.

  • TypeProtection
  • SystemCompressor / inverter
  • Can I fix it?Technician job
  • Applies toBMY / BMX S-series (Midea table, four-character codes)

What PC 44 means on a Blueridge

The drive commanded the compressor to run but detected no rotation. The compressor may be seized, or the drive cannot start it.

On this platform, PC 44 is a protection: the system stopped or throttled itself to prevent damage; many clear on their own once conditions return to normal.

Common causes

  • A seized or stuck compressor.
  • A failed inverter drive.
  • Liquid refrigerant in the compressor after sitting cold.
  • Low supply voltage.

How to fix it yourself

Do the reset and the visual checks, but the underlying repair needs a technician with a meter and the service manual.

  1. Reset the system: switch the breaker (or the outdoor disconnect) off, wait a full five minutes so the boards fully discharge, then switch it back on and restart from the remote.
  2. If you own a multimeter and are comfortable using it, measure the supply voltage at the outdoor unit's L1 and L2 terminals with the unit running. A 230 V system should read roughly 208 to 253 VAC.
  3. Do not keep retrying; if it will not start after two attempts, stop.

Switch off power at the breaker before opening either unit. Capacitors in the outdoor unit hold a charge for several minutes after power is cut.

When to call a technician

Technician diagnosis of the compressor and drive.

Which Blueridge units show PC 44

This page applies to Blueridge BMKH wall-mount, floor-ceiling and multi-zone (2016 and later) and BMY / BMX S-series single-zone (2023 and later) units on the BMY / BMX S-series (Midea table, four-character codes). Blueridge's own documentation lists PC 44 as "Compressor zero-speed protection", the same definition used across the Midea platform (four-character codes) it is built on. If your unit shows a code with a different shape (for example a four-character code, or a plain number), it is from a different table; use the lookup with your exact code.

Where Blueridge shows this code

BMY / BMX S-series (Midea table, four-character codes): The display shows a two-letter prefix and a two-character suffix, either together (EH60) or alternating (EH, then 60). Write both parts down; the suffix is what identifies the fault. EH and EL are indoor-side faults, EC is an outdoor-side fault, and PC is an outdoor protection: the unit stopped itself to prevent damage.

Other Blueridge codes

Same part of the system as PC 44:

All Blueridge error codes

PC 44 on other brands

The same characters do not always mean the same thing. Check the brand on your unit.

Questions people ask

Can I reset a Blueridge PC 44 code myself?

Yes. Turn the system off at the breaker for five minutes, then restart it. If PC 44 comes back, the fault is real and needs the checks above.

Is it safe to keep running a Blueridge showing PC 44?

Not repeatedly. A protection code means the unit stopped itself to prevent damage, and resetting it over and over can turn a cheap repair into a compressor failure. Reset once, check the basics, and stop if it returns.

What will a technician check for PC 44?

Technician diagnosis of the compressor and drive. Ask for the measurements, not just a parts quote.

Sources

  • Blueridge Installation and Owner's Manual (BMKH, 11/2016 and 01/2017 editions), Diagnostic Codes
  • Blueridge BMKH Floor-Ceiling User and Install Manual (12/2023), error code table
  • Blueridge BMY19 Series Owner's Manual and DIY Single Zone Installation Manual (2020), Midea document CS78421-548-754 (same manual family as Pioneer WYT)

Updated September 2026. Codes and definitions vary by model year. If your manual disagrees with this page, your manual wins. Send a correction.