DIY HVAC Tools

Daikin mini split error code CA

Indoor discharge air temperature sensor fault (open or short circuit).

  • TypeFault
  • SystemTemperature sensor
  • Can I fix it?Homeowner checks, then maybe a tech

What CA means on a Daikin

The control board is reading the indoor discharge air temperature sensor as open or shorted, which means the thermistor (a small resistor whose resistance changes with temperature) is returning a value outside its normal range. The unit usually stops, or runs with the wrong output, because the control board no longer trusts that temperature reading.

On this platform, CA is a fault: something has failed or is disconnected and needs diagnosis.

Common causes

  • The indoor discharge air temperature thermistor has failed (they do drift and fail with age and heat cycling).
  • Its plug has worked loose from the control board, or a pin has corroded.
  • The sensor lead is chafed, pinched or chewed, giving an intermittent open or short.
  • The control board's sensor input has failed (rare compared with the sensor itself).

How to fix it yourself

Work through the checks below first; they resolve most cases. If they do not, the repair itself may need a technician.

  1. Reset the system: switch the breaker (or the outdoor disconnect) off, wait a full five minutes so the boards fully discharge, then switch it back on and restart from the remote.
  2. If the code comes straight back after a reset, the fault is real and not a glitch.
  3. With power off, locate the indoor discharge air temperature sensor near the air outlet. Follow its lead back to the board and reseat the plug firmly.
  4. Inspect the lead for damage along its whole length, especially where it passes through the chassis.
  5. If you have a multimeter, unplug the sensor and measure its resistance. A reading near zero ohms (short) or infinite (open) confirms a bad sensor. Most mini split thermistors read roughly 5 to 20 kΩ at room temperature, so a value in that range with a steady drift as you warm it in your hand means the sensor is fine and the board is the suspect.
  6. Replacement thermistors are inexpensive and plug in. Match the part number from the parts list for your model.

Switch off power at the breaker before opening either unit. Capacitors in the outdoor unit hold a charge for several minutes after power is cut.

When to call a technician

Sensor swaps are a doable DIY job on most units. Call a technician if the sensor tests good and the code persists, because that points at the control board.

Which Daikin units show CA

This page applies to Daikin Aurora, 19 Series, Atmosphera, Emura, Quaternity and MXS multi-zone units. Daikin's own documentation lists CA as "Indoor discharge air temperature sensor fault (open or short circuit)", the same definition used across the Daikin it is built on. If your unit shows a code with a different shape (for example a four-character code, or a plain number), it is from a different table; use the lookup with your exact code.

Where Daikin shows this code

Most Daikin wall units do not show the code on the unit; the operation lamp blinks. To read the code, point the remote at the unit, hold CANCEL (or Timer Cancel) for about 5 seconds until 00 shows, then press CANCEL repeatedly. Each press shows a code; when the unit gives a long continuous beep instead of two short beeps, the code on the remote is the stored fault. Units with a wired controller show the code directly. A and C codes are indoor-unit faults, E, F, H, J, L and P codes are outdoor-unit faults and protections, and U codes are system-level problems such as communication, power supply and refrigerant shortage.

Other Daikin codes

Same part of the system as CA:

All Daikin error codes

CA on other brands

The same characters do not always mean the same thing. Check the brand on your unit.

  • Goodman CA Indoor discharge air temperature sensor fault (open or short circuit)

Questions people ask

Can I reset a Daikin CA code myself?

Yes. Turn the system off at the breaker for five minutes, then restart it. If CA comes back, the fault is real and needs the checks above.

Is it safe to keep running a Daikin showing CA?

The unit will usually refuse to run, or run with reduced output, until the fault is cleared. Repeated resets do not fix anything and can mask a problem that is getting worse.

Do I need a technician for Daikin CA?

Work through the checks below first; they resolve most cases. If they do not, the repair itself may need a technician. Sensor swaps are a doable DIY job on most units. Call a technician if the sensor tests good and the code persists, because that points at the control board.

Sources

  • Daikin residential (RA) service manuals (error code tables)
  • Daikin operation manuals (remote controller self-diagnosis)

Updated September 2026. Codes and definitions vary by model year. If your manual disagrees with this page, your manual wins. Send a correction.