Daikin mini split error code E1
Outdoor unit control board (PCB) failure.
- TypeFault
- SystemControl board
- Can I fix it?Technician job
What E1 means on a Daikin
The outdoor control board failed its self-check.
On this platform, E1 is a fault: something has failed or is disconnected and needs diagnosis.
Common causes
- A surge or lightning event.
- A failed board.
How to fix it yourself
Do the reset and the visual checks, but the underlying repair needs a technician with a meter and the service manual.
- Reset the system: switch the breaker (or the outdoor disconnect) off, wait a full five minutes so the boards fully discharge, then switch it back on and restart from the remote.
- If the code comes straight back after a reset, the fault is real and not a glitch.
Switch off power at the breaker before opening either unit. Capacitors in the outdoor unit hold a charge for several minutes after power is cut.
When to call a technician
Board replacement by a technician.
Which Daikin units show E1
This page applies to Daikin Aurora, 19 Series, Atmosphera, Emura, Quaternity and MXS multi-zone units. Daikin's own documentation lists E1 as "Outdoor unit control board (PCB) failure", the same definition used across the Daikin it is built on. If your unit shows a code with a different shape (for example a four-character code, or a plain number), it is from a different table; use the lookup with your exact code.
Where Daikin shows this code
Most Daikin wall units do not show the code on the unit; the operation lamp blinks. To read the code, point the remote at the unit, hold CANCEL (or Timer Cancel) for about 5 seconds until 00 shows, then press CANCEL repeatedly. Each press shows a code; when the unit gives a long continuous beep instead of two short beeps, the code on the remote is the stored fault. Units with a wired controller show the code directly. A and C codes are indoor-unit faults, E, F, H, J, L and P codes are outdoor-unit faults and protections, and U codes are system-level problems such as communication, power supply and refrigerant shortage.
Other Daikin codes
Same part of the system as E1:
E1 on other brands
The same characters do not always mean the same thing. Check the brand on your unit.
- Pioneer E1 Communication error between indoor and outdoor units
- Blueridge E1 High pressure protection / Communication error between indoor and outdoor units
- Gree E1 High pressure protection
- Zone Air E1 Indoor room temperature sensor fault (open or short circuit)
- Mitsubishi Electric E1 Remote controller control board fault
- Trane E1 Indoor room temperature sensor fault (open or short circuit) / Remote controller control board fault
- Heil E1 Communication error between indoor and outdoor units / High pressure protection
- ACiQ E1 Communication error between indoor and outdoor units / Indoor room temperature sensor fault (open or short circuit)
- Goodman E1 Outdoor unit control board (PCB) failure
Questions people ask
Can I reset a Daikin E1 code myself?
Yes. Turn the system off at the breaker for five minutes, then restart it. If E1 comes back, the fault is real and needs the checks above.
Is it safe to keep running a Daikin showing E1?
The unit will usually refuse to run, or run with reduced output, until the fault is cleared. Repeated resets do not fix anything and can mask a problem that is getting worse.
What will a technician check for E1?
Board replacement by a technician. Ask for the measurements, not just a parts quote.
Sources
- Daikin residential (RA) service manuals (error code tables)
- Daikin operation manuals (remote controller self-diagnosis)
Updated September 2026. Codes and definitions vary by model year. If your manual disagrees with this page, your manual wins. Send a correction.