Bosch mini split error code PC 0A
Condenser high temperature protection. Also shown as PC0A.
- TypeProtection
- SystemRefrigerant circuit
- Can I fix it?Homeowner checks, then maybe a tech
- Applies toindoor unit display (four-character codes)
What PC 0A means on a Bosch
The outdoor coil (condenser) temperature climbed too high in cooling mode and the unit reduced or stopped output to protect itself.
On this platform, PC 0A is a protection: the system stopped or throttled itself to prevent damage; many clear on their own once conditions return to normal.
Common causes
- A dirty or blocked outdoor coil.
- An outdoor fan running slow or stopped.
- The unit installed with too little clearance, recirculating its own hot air.
- Extreme outdoor temperatures.
How to fix it yourself
Work through the checks below first; they resolve most cases. If they do not, the repair itself may need a technician.
- Look at the outdoor unit: clear leaves, cottonwood fluff, snow or ice from the coil and make sure the fan can spin freely and nothing is stacked against the cabinet.
- Hose the outdoor coil from the inside out (power off) if it is visibly dirty.
- Check that the fan spins freely and runs when cooling.
- Make sure the clearance around the outdoor unit matches the manual (typically 12 in. or more on the coil side and 24 in. at the fan discharge).
Switch off power at the breaker before opening either unit. Capacitors in the outdoor unit hold a charge for several minutes after power is cut.
When to call a technician
If the coil is clean and the fan is fine, have a technician check the charge and the T3 sensor.
Which Bosch units show PC 0A
This page applies to Bosch Climate 5000 and Climate 5000 Multi units on the indoor unit display (four-character codes). Bosch's own documentation lists PC 0A as "Condenser high temperature protection", the same definition used across the Midea platform (four-character codes) it is built on. If your unit shows a code with a different shape (for example a four-character code, or a plain number), it is from a different table; use the lookup with your exact code.
Where Bosch shows this code
indoor unit display (four-character codes): The display shows a two-letter prefix and a two-character suffix, either together (EH60) or alternating (EH, then 60). Write both parts down; the suffix is what identifies the fault. EH and EL are indoor-side faults, EC is an outdoor-side fault, and PC is an outdoor protection: the unit stopped itself to prevent damage.
Other Bosch codes
Same part of the system as PC 0A:
PC 0A on other brands
The same characters do not always mean the same thing. Check the brand on your unit.
- Pioneer PC 0A Condenser high temperature protection
Questions people ask
Can I reset a Bosch PC 0A code myself?
Yes. Turn the system off at the breaker for five minutes, then restart it. If PC 0A comes back, the fault is real and needs the checks above.
Is it safe to keep running a Bosch showing PC 0A?
Not repeatedly. A protection code means the unit stopped itself to prevent damage, and resetting it over and over can turn a cheap repair into a compressor failure. Reset once, check the basics, and stop if it returns.
Do I need a technician for Bosch PC 0A?
Work through the checks below first; they resolve most cases. If they do not, the repair itself may need a technician. If the coil is clean and the fan is fine, have a technician check the charge and the T3 sensor.