Panasonic residential splits use H codes for faults and F codes for protections, read from the remote's check mode.

Covers: Exterios, ClimaPure, Multi-zone (CU-xE).

Type it exactly as the unit shows it. Not sure which brand? It is printed on the front of the indoor unit.

All Panasonic codes

34 codes. Type to filter the list.

CodeMeaningTypeFix
H11Communication error between indoor and outdoor unitsFaultDIY checks
H12Indoor and outdoor capacity mismatch (multi-split)FaultDIY checks
H14Indoor intake (room) air temperature sensor fault (open or short circuit)FaultDIY checks
H15Outdoor compressor temperature sensor fault (open or short circuit)FaultDIY checks
H16Outdoor current transformer (CT) fault or low currentFaultTechnician
H17Outdoor suction temperature sensor fault (open or short circuit)FaultDIY checks
H19Indoor fan motor lockedFaultDIY checks
H21Indoor float switch operated (drain)FaultDIY
H23Indoor heat exchanger (pipe) temperature sensor fault (open or short circuit)FaultDIY checks
H24Indoor heat exchanger temperature sensor (second sensor) fault (open or short circuit)FaultDIY checks
H25Ion generator (nanoe or e-ion) faultFaultDIY
H27Outdoor air temperature sensor fault (open or short circuit)FaultDIY checks
H28Outdoor heat exchanger (pipe) temperature sensor fault (open or short circuit)FaultDIY checks
H30Outdoor discharge pipe temperature sensor fault (open or short circuit)FaultDIY checks
H33Indoor and outdoor misconnection (wrong voltage or model)FaultDIY checks
H34Inverter heat sink temperature sensor faultFaultDIY checks
H36Outdoor gas pipe temperature sensor fault (open or short circuit)FaultDIY checks
H37Outdoor liquid pipe temperature sensor fault (open or short circuit)FaultDIY checks
H38Indoor and outdoor brand mismatchFaultDIY checks
H39Abnormal indoor operating unit (multi-split)ProtectionDIY checks
H41Abnormal wiring or piping connection (multi-split)FaultDIY checks
H97Outdoor fan motor lockedFaultDIY checks
H98Indoor high pressure protection (heating)ProtectionDIY
H99Indoor freeze prevention (cooling)ProtectionDIY
F11Four-way (reversing) valve switching faultFaultTechnician
F17Indoor standby unit freezing (multi-split)ProtectionDIY checks
F90PFC (power factor correction) protectionProtectionTechnician
F91Refrigeration cycle abnormal (low charge or blockage)FaultDIY checks
F93Compressor abnormal rotationProtectionTechnician
F95Outdoor high pressure protection (cooling)ProtectionDIY checks
F96Power module (IPM) overheatingProtectionDIY checks
F97Compressor overheating (discharge temperature too high)ProtectionDIY checks
F98Total running current protection (over-current)ProtectionDIY checks
F99Outdoor DC peak detection (inverter over-current)ProtectionTechnician

How Panasonic shows error codes

The indoor unit blinks its Timer lamp when a fault is stored. To read the code, point the remote at the unit and hold the CHECK button (on the back of the remote, under the flap on most models) for about 5 seconds until -- shows, then press the temperature up or down button; each press shows a code, and the unit beeps continuously (not a short beep) when the code shown is the stored fault. H codes are faults (a sensor, motor or board that needs attention). F codes are protections: the outdoor unit stopped itself because of pressure, temperature or current.

Sources

  • Panasonic residential split service manuals (H/F code tables)

Updated September 2026. Manufacturer site: na.panasonic.com/us/heating-air-conditioning