Heil mini split error codes
Heil ductless systems come from ICP (Carrier's sister company) and have used two makers. The current DLC/DLF series (DLCSRA, DLCSRB, DLFSHA and related) is Midea-built and uses the Midea code set. The earlier DLC4 / DLF4 series (2013 to 2015) is Gree-built and uses the Gree set, so E1, E5 and F1 mean different things on the two generations.
Covers: DLCSRA / DLCSRB / DLCLRA outdoor with DLFSHA / DLFSFA indoor (2015 and later), DLC4 / DLF4 (2013 to 2015).
Most looked-up Heil codes
All Heil codes
66 codes. Type to filter the list.
Filter codes
Code Meaning Type Fix
E0 Indoor unit EEPROM parameter error Fault DIY checks E1 DLC/DLF series, 2015 and later (Midea-built): Communication error between indoor and outdoor unitsDLC4 / DLF4 series, 2013 to 2015 (Gree-built): High pressure protectionVaries DIY checks E2 DLC/DLF series, 2015 and later (Midea-built): Zero-crossing signal detection errorDLC4 / DLF4 series, 2013 to 2015 (Gree-built): Indoor anti-freeze protectionVaries DIY checks E3 DLC/DLF series, 2015 and later (Midea-built): Indoor fan speed out of control (indoor fan motor fault)DLC4 / DLF4 series, 2013 to 2015 (Gree-built): Low pressure protection (refrigerant shortage or blockage)Varies DIY checks E4 DLC/DLF series, 2015 and later (Midea-built): Indoor room temperature sensor (T1) open or short circuitDLC4 / DLF4 series, 2013 to 2015 (Gree-built): Compressor discharge temperature too highVaries DIY checks E5 DLC/DLF series, 2015 and later (Midea-built): Evaporator coil temperature sensor (T2) open or short circuitDLC4 / DLF4 series, 2013 to 2015 (Gree-built): Over-current protectionVaries DIY checks EC Refrigerant leak detected (low refrigerant charge) Fault DIY checks F0 DLC/DLF series, 2015 and later (Midea-built): Overload current protection (compressor over-current)DLC4 / DLF4 series, 2013 to 2015 (Gree-built): Refrigerant shortage or system blockage detectedVaries DIY checks EB Communication error between indoor main board and display board Fault DIY checks EF Intelligent eye (occupancy sensor) module error Fault DIY F1 DLC/DLF series, 2015 and later (Midea-built): Outdoor ambient temperature sensor (T4) open or short circuitDLC4 / DLF4 series, 2013 to 2015 (Gree-built): Indoor ambient (room) temperature sensor fault (open or short circuit)Fault DIY checks F2 DLC/DLF series, 2015 and later (Midea-built): Condenser coil temperature sensor (T3) open or short circuitDLC4 / DLF4 series, 2013 to 2015 (Gree-built): Indoor evaporator coil temperature sensor fault (open or short circuit)Fault DIY checks F3 DLC/DLF series, 2015 and later (Midea-built): Compressor discharge temperature sensor (TP) open or short circuitDLC4 / DLF4 series, 2013 to 2015 (Gree-built): Outdoor ambient temperature sensor fault (open or short circuit)Fault DIY checks F4 DLC/DLF series, 2015 and later (Midea-built): Outdoor unit EEPROM parameter errorDLC4 / DLF4 series, 2013 to 2015 (Gree-built): Outdoor condenser coil (middle) temperature sensor fault (open or short circuit)Fault Technician F5 DLC/DLF series, 2015 and later (Midea-built): Outdoor fan speed out of control (outdoor fan motor fault)DLC4 / DLF4 series, 2013 to 2015 (Gree-built): Compressor discharge temperature sensor fault (open or short circuit)Fault DIY checks P0 DLC/DLF series, 2015 and later (Midea-built): Inverter module (IPM) malfunctionDLC4 / DLF4 series, 2013 to 2015 (Gree-built): IPM reset (drive module restarted)Protection Technician P1 Over-voltage or under-voltage protection Protection DIY checks P2 High temperature protection (compressor top or inverter module) Protection DIY checks P3 Outdoor temperature too low protection (heating lockout) Protection DIY P4 Inverter compressor drive error Protection Technician P5 DLC/DLF series, 2015 and later (Midea-built): Mode conflict (multi-zone)DLC4 / DLF4 series, 2013 to 2015 (Gree-built): Compressor current protectionProtection DIY P6 DLC/DLF series, 2015 and later (Midea-built): Outdoor low pressure protectionDLC4 / DLF4 series, 2013 to 2015 (Gree-built): Communication error between inverter drive and main controllerVaries DIY checks dF Defrost cycle running Status DIY CL Filter cleaning reminder Status DIY AP Wi-Fi pairing (access point) mode Status DIY E6 Communication error between indoor and outdoor units Fault DIY checks E7 Mode conflict (multi-zone) Protection DIY E8 High temperature protection (overheating) Protection DIY checks E9 Indoor unit water-full (drain) protection Protection DIY EE EEPROM (memory) error on a control board Fault Technician Fo Refrigerant recovery (pump-down) mode Status DIY F6 Overload frequency limiting (protection) Protection DIY F8 Over-current frequency limiting (protection) Protection DIY F9 High discharge temperature frequency limiting (protection) Protection DIY FH Anti-freeze frequency limiting (protection) Protection DIY H1 Defrost cycle running Status DIY H3 Compressor overload protection Protection DIY checks H4 System overload protection Protection DIY checks H5 IPM (inverter module) protection Protection Technician H6 Indoor fan motor not running (no feedback) Fault DIY checks H7 Compressor desynchronization (loss of sync) Protection Technician HC PFC (power factor correction) protection Protection Technician U7 Four-way (reversing) valve fault Fault Technician U8 Indoor fan (PG motor) zero-crossing detection error Fault DIY checks C5 Jumper cap malfunction (missing or wrong jumper) Fault DIY checks PH DC bus high voltage (over-voltage) protection Protection DIY checks PL DC bus low voltage (under-voltage) protection Protection DIY checks Lc Compressor start failure Protection Technician Ld Compressor phase loss or phase sequence error Protection Technician LE Compressor stall (locked rotor) Protection Technician LP Indoor and outdoor unit mismatch Fault DIY checks oE Outdoor unit fault (see outdoor board) Fault Technician U5 Whole-unit current detection error Fault Technician F7 Oil return cycle (cooling) Status DIY LA Outdoor DC fan motor error Fault DIY checks LF Compressor over-speed protection Protection Technician P7 Inverter heat sink temperature sensor error Fault DIY checks P8 Inverter heat sink (radiator) overheat protection Protection DIY checks P9 AC contactor protection Protection Technician Pc Current sensor error Fault Technician Pd Sensor connection protection Fault Technician PE Temperature drift protection Protection Technician PF Drive board ambient temperature sensor error Fault DIY checks PA AC current protection Protection DIY checks PU Charging circuit error Fault Technician PP AC input voltage anomaly Protection DIY checks
No code matches that. Check the characters (b and 6, 0 and o, and E and F are easy to confuse) or try another brand .
How Heil shows error codes
DLC/DLF series, 2015 and later (Midea-built): The code appears on the indoor unit's LED display in place of the set temperature. Some models also blink the indicator lamps in a pattern that matches the code. E codes are faults in the indoor unit or its communication link, F codes are faults on the outdoor side, and P codes are protections: the outdoor unit has stopped itself to prevent damage. EC is the refrigerant leak check.
DLC4 / DLF4 series, 2013 to 2015 (Gree-built): The code shows on the indoor unit's display in place of the temperature. If the display is off, press the Light button on the remote. Some models also count out the code as indicator blinks. E codes are system protections and faults, F codes are mostly sensor faults, H codes are outdoor and compressor protections, U codes are motor and valve faults, and P codes are power-supply faults.
Brands built on the same platform
These brands share a code table with Heil because the same factory builds them, so their pages describe the same faults: ACiQ , AirEase , Arcoaire , Arctic King , Armstrong Air , Blueridge , Bosch , Bryant , Carrier , Comfortmaker , Concord , Cooper & Hunter , Day & Night , Della .
Sources
ICP DLCSRA Outdoor Unit Single Zone Ductless Service Manual 32808000801 (error code table) ICP ductless installation instructions IM-KSAIC04-04 (DLCPRA / DLCSRB / DLCERB / DLCLRA error codes) ICP R-410A Ductless Split System Service Manual 421 01 9204 00 (DLC4 / DLF4, 2013)
Updated September 2026. Manufacturer site: www.heil-hvac.com