Mitsubishi Electric mini split error code P2

Indoor pipe (liquid) temperature sensor fault (open or short circuit).

  • TypeFault
  • SystemTemperature sensor
  • Can I fix it?Homeowner checks, then maybe a tech

What P2 means on a Mitsubishi Electric

The control board is reading the indoor pipe (liquid) temperature sensor as open or shorted, which means the thermistor (a small resistor whose resistance changes with temperature) is returning a value outside its normal range. The unit usually stops, or runs with the wrong output, because the control board no longer trusts that temperature reading.

On this platform, P2 is a fault: something has failed or is disconnected and needs diagnosis.

Common causes

  • The indoor pipe (liquid) temperature thermistor has failed (they do drift and fail with age and heat cycling).
  • Its plug has worked loose from the control board, or a pin has corroded.
  • The sensor lead is chafed, pinched or chewed, giving an intermittent open or short.
  • The control board's sensor input has failed (rare compared with the sensor itself).

How to fix it yourself

Work through the checks below first; they resolve most cases. If they do not, the repair itself may need a technician.

  1. Reset the system: switch the breaker (or the outdoor disconnect) off, wait a full five minutes so the boards fully discharge, then switch it back on and restart from the remote.
  2. If the code comes straight back after a reset, the fault is real and not a glitch.
  3. With power off, locate the indoor pipe (liquid) temperature sensor on the refrigerant pipe at the indoor coil. Follow its lead back to the board and reseat the plug firmly.
  4. Inspect the lead for damage along its whole length, especially where it passes through the chassis.
  5. If you have a multimeter, unplug the sensor and measure its resistance. A reading near zero ohms (short) or infinite (open) confirms a bad sensor. Most mini split thermistors read roughly 5 to 20 kΩ at room temperature, so a value in that range with a steady drift as you warm it in your hand means the sensor is fine and the board is the suspect.
  6. Replacement thermistors are inexpensive and plug in. Match the part number from the parts list for your model.

Switch off power at the breaker before opening either unit. Capacitors in the outdoor unit hold a charge for several minutes after power is cut.

When to call a technician

Sensor swaps are a doable DIY job on most units. Call a technician if the sensor tests good and the code persists, because that points at the control board.

Which Mitsubishi Electric units show P2

This page applies to Mitsubishi Electric M-Series (MSZ), Mr. Slim (PKA/PCA), Hyper-Heating H2i and MXZ multi-zone units. Mitsubishi Electric's own documentation lists P2 as "Indoor pipe (liquid) temperature sensor fault (open or short circuit)", the same definition used across the Mitsubishi Electric it is built on. If your unit shows a code with a different shape (for example a four-character code, or a plain number), it is from a different table; use the lookup with your exact code.

Where Mitsubishi Electric shows this code

Wall units without a wired controller signal a fault by blinking the operation indicator lamp; the code itself shows on a wired controller (MHK/PAR series) or on the wireless remote after entering its check mode (see your manual). On the outdoor unit, the control board LEDs blink the same code. P codes are indoor-unit faults, E codes are communication faults, F codes are outdoor-unit faults and U codes are outdoor-unit and compressor faults.

Other Mitsubishi Electric codes

Same part of the system as P2:

All Mitsubishi Electric error codes

P2 on other brands

The same characters do not always mean the same thing. Check the brand on your unit.

  • Pioneer P2 High temperature protection (compressor top or inverter module) / Low pressure protection (outdoor display)
  • Blueridge P2 High temperature protection (compressor top or inverter module)
  • Zone Air P2 Over-current protection
  • Trane P2 Over-current protection / Indoor pipe (liquid) temperature sensor fault (open or short circuit)
  • ACiQ P2 High temperature protection (compressor top or inverter module) / Over-current protection

Questions people ask

Can I reset a Mitsubishi Electric P2 code myself?

Yes. Turn the system off at the breaker for five minutes, then restart it. If P2 comes back, the fault is real and needs the checks above.

Is it safe to keep running a Mitsubishi Electric showing P2?

The unit will usually refuse to run, or run with reduced output, until the fault is cleared. Repeated resets do not fix anything and can mask a problem that is getting worse.

Do I need a technician for Mitsubishi Electric P2?

Work through the checks below first; they resolve most cases. If they do not, the repair itself may need a technician. Sensor swaps are a doable DIY job on most units. Call a technician if the sensor tests good and the code persists, because that points at the control board.

Sources

  • Mitsubishi Electric M-Series and Mr. Slim service manuals (self-diagnosis tables)

Updated September 2026. Codes and definitions vary by model year. If your manual disagrees with this page, your manual wins. Send a correction.