DIY HVAC Tools

LG mini split error code CH62

Inverter heat sink temperature too high. Also shown as CH 62, CH62.

  • TypeProtection
  • SystemCompressor / inverter
  • Can I fix it?Homeowner checks, then maybe a tech

What CH62 means on a LG

The inverter's heat sink got too hot and the compressor stopped.

On this platform, CH62 is a protection: the system stopped or throttled itself to prevent damage; many clear on their own once conditions return to normal.

Common causes

  • A blocked outdoor coil or failed fan.
  • Blocked clearance around the outdoor unit.

How to fix it yourself

Work through the checks below first; they resolve most cases. If they do not, the repair itself may need a technician.

  1. Look at the outdoor unit: clear leaves, cottonwood fluff, snow or ice from the coil and make sure the fan can spin freely and nothing is stacked against the cabinet.
  2. Check clearance around the outdoor unit.
  3. Reset the system: switch the breaker (or the outdoor disconnect) off, wait a full five minutes so the boards fully discharge, then switch it back on and restart from the remote.

Switch off power at the breaker before opening either unit. Capacitors in the outdoor unit hold a charge for several minutes after power is cut.

When to call a technician

Persistent CH62 with a clean coil needs a technician.

Which LG units show CH62

This page applies to LG Art Cool, Standard, Mega and Multi F units. LG's own documentation lists CH62 as "Inverter heat sink temperature too high", the same definition used across the LG it is built on. If your unit shows a code with a different shape (for example a four-character code, or a plain number), it is from a different table; use the lookup with your exact code.

Where LG shows this code

The indoor display shows CH followed by a number (CH05, CH38). Units without a display blink the indicator lamps in a pattern; the outdoor board LEDs blink the same number. If someone tells you 'CH 5', that is CH05. CH01 to CH12 are indoor-unit faults, CH21 to CH29 are inverter and compressor faults, CH32 to CH38 are refrigerant-side protections, CH40 to CH48 are outdoor sensors, and CH51 to CH73 are outdoor-unit system faults.

Other LG codes

Same part of the system as CH62:

All LG error codes

Questions people ask

Can I reset a LG CH62 code myself?

Yes. Turn the system off at the breaker for five minutes, then restart it. If CH62 comes back, the fault is real and needs the checks above.

Is it safe to keep running a LG showing CH62?

Not repeatedly. A protection code means the unit stopped itself to prevent damage, and resetting it over and over can turn a cheap repair into a compressor failure. Reset once, check the basics, and stop if it returns.

Do I need a technician for LG CH62?

Work through the checks below first; they resolve most cases. If they do not, the repair itself may need a technician. Persistent CH62 with a clean coil needs a technician.