Daikin mini split error code LC
Communication error between outdoor control and inverter boards.
- TypeFault
- SystemCommunication
- Can I fix it?Technician job
What LC means on a Daikin
The two boards inside the outdoor unit stopped talking to each other.
On this platform, LC is a fault: something has failed or is disconnected and needs diagnosis.
Common causes
- A loose connector between the boards.
- A failed board.
- Water or corrosion on the connectors.
How to fix it yourself
Do the reset and the visual checks, but the underlying repair needs a technician with a meter and the service manual.
- Reset the system: switch the breaker (or the outdoor disconnect) off, wait a full five minutes so the boards fully discharge, then switch it back on and restart from the remote.
- With power off, reseat the connectors between the outdoor boards.
Switch off power at the breaker before opening either unit. Capacitors in the outdoor unit hold a charge for several minutes after power is cut.
When to call a technician
Board-level fault.
Which Daikin units show LC
This page applies to Daikin Aurora, 19 Series, Atmosphera, Emura, Quaternity and MXS multi-zone units. Daikin's own documentation lists LC as "Communication error between outdoor control and inverter boards", the same definition used across the Daikin it is built on. If your unit shows a code with a different shape (for example a four-character code, or a plain number), it is from a different table; use the lookup with your exact code.
Where Daikin shows this code
Most Daikin wall units do not show the code on the unit; the operation lamp blinks. To read the code, point the remote at the unit, hold CANCEL (or Timer Cancel) for about 5 seconds until 00 shows, then press CANCEL repeatedly. Each press shows a code; when the unit gives a long continuous beep instead of two short beeps, the code on the remote is the stored fault. Units with a wired controller show the code directly. A and C codes are indoor-unit faults, E, F, H, J, L and P codes are outdoor-unit faults and protections, and U codes are system-level problems such as communication, power supply and refrigerant shortage.
Other Daikin codes
Same part of the system as LC:
LC on other brands
The same characters do not always mean the same thing. Check the brand on your unit.
- Blueridge Lc Compressor start failure
- Goodman LC Communication error between outdoor control and inverter boards
Questions people ask
Can I reset a Daikin LC code myself?
Yes. Turn the system off at the breaker for five minutes, then restart it. If LC comes back, the fault is real and needs the checks above.
Is it safe to keep running a Daikin showing LC?
The unit will usually refuse to run, or run with reduced output, until the fault is cleared. Repeated resets do not fix anything and can mask a problem that is getting worse.
What will a technician check for LC?
Board-level fault. Ask for the measurements, not just a parts quote.
Sources
- Daikin residential (RA) service manuals (error code tables)
- Daikin operation manuals (remote controller self-diagnosis)
Updated September 2026. Codes and definitions vary by model year. If your manual disagrees with this page, your manual wins. Send a correction.