DIY HVAC Tools

Comfortmaker mini split code AP

Wi-Fi pairing (access point) mode.

  • TypeStatus, not a fault
  • SystemDisplay
  • Can I fix it?Usually a homeowner fix
  • Applies toDLC/DLF series, 2015 and later (Midea-built)

What AP means on a Comfortmaker

The unit's Wi-Fi module is broadcasting its own network so the app can connect and configure it. It shows AP during setup, and sometimes after a power interruption if the module reboots.

On this platform, AP is a status, not a fault: the unit is telling you what it is doing; nothing is wrong.

What to do

You can almost always clear this yourself with the steps below.

  1. Finish pairing in the manufacturer's app, or wait; the unit exits AP mode on its own after several minutes.
  2. To force it out, turn the unit off and on with the remote.

When to call a technician

This is not a fault. No technician is needed unless it will not clear.

Which Comfortmaker units show AP

This page applies to Comfortmaker DLCSRA / DLCSRB / DLCLRA outdoor with DLFSHA / DLFSFA indoor (2015 and later) and DLC4 / DLF4 (2013 to 2015) units on the DLC/DLF series, 2015 and later (Midea-built). Comfortmaker's own documentation lists AP as "Wi-Fi pairing (access point) mode", the same definition used across the Midea platform (classic codes) it is built on. If your unit shows a code with a different shape (for example a four-character code, or a plain number), it is from a different table; use the lookup with your exact code.

Where Comfortmaker shows this code

DLC/DLF series, 2015 and later (Midea-built): The code appears on the indoor unit's LED display in place of the set temperature. Some models also blink the indicator lamps in a pattern that matches the code. E codes are faults in the indoor unit or its communication link, F codes are faults on the outdoor side, and P codes are protections: the outdoor unit has stopped itself to prevent damage. EC is the refrigerant leak check.

Other Comfortmaker codes

Same part of the system as AP:

All Comfortmaker error codes

AP on other brands

The same characters do not always mean the same thing. Check the brand on your unit.

Questions people ask

Is AP on a Comfortmaker mini split an error?

No. AP is a status message: wi-Fi pairing (access point) mode. The unit's Wi-Fi module is broadcasting its own network so the app can connect and configure it.

Do I need a technician for Comfortmaker AP?

You can almost always clear this yourself with the steps below. This is not a fault. No technician is needed unless it will not clear.

Sources

  • ICP DLCSRA Outdoor Unit Single Zone Ductless Service Manual 32808000801 (error code table)
  • ICP ductless installation instructions IM-KSAIC04-04 (DLCPRA / DLCSRB / DLCERB / DLCLRA error codes)
  • ICP R-410A Ductless Split System Service Manual 421 01 9204 00 (DLC4 / DLF4, 2013)

Updated September 2026. Codes and definitions vary by model year. If your manual disagrees with this page, your manual wins. Send a correction.